Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS300SSEA0AAAA — OEM | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS300SSEA0AAAA — OEM | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM igniter electrode, ICP part number 1179966, is the hot surface ignition element that lights the burners on your RGS300SSEA0AAAA gas furnace. On each heat call, the control board sends line voltage to the igniter, which glows incandescent-hot and ignites the gas as it flows across the burners. Igniters are brittle and degrade with every thermal cycle, so they are one of the most common no-heat failures. A cracked or open igniter leaves the furnace unable to start a burner cycle even though the blower and controls are working normally.

Specifications

Spec Value
OEM Part Number 1179966
Type Hot Surface Igniter / Ignitor Electrode
Brand ICP / Tempstar / Heil
Function Burner Ignition
Application Gas Furnace
Fitment OEM Direct Replacement

Compatibility

Engineered as the factory replacement for the ICP/Tempstar/Heil RGS300SSEA0AAAA and related RGS-series gas furnaces that call out OEM part 1179966. Handle the ceramic element only by its bracket — skin oils and impacts shorten its life. Confirm the mounting bracket and connector match your existing igniter before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position, bracket, and wire routing before removing it.
  4. Remove — Unplug the igniter connector and unfasten the mounting screw, then lift the old igniter clear.
  5. Install — Set the new igniter so the element aligns to the burner port, handling it only by the bracket, and plug in the connector.
  6. Test — Restore power and confirm the igniter glows and lights the burners on a heat call.

Signs You Need a Replacement

  • Furnace runs the ignition sequence but no flame appears.
  • Igniter shows visible cracks, blisters, or no longer glows.
  • Furnace locks out after several failed ignition attempts.
  • Measured resistance is open or far outside the normal range.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS300SSEA0AAAA — OEM | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS300SSEA0AAAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS300SSEA0AAAA — OEM | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.