This is the genuine OEM ignitor electrode (part number 1179966) for the ICP Tempstar Heil RGS300LEFA0AAAA gas furnace. The igniter electrode produces the high-voltage spark or hot surface that lights the burners on every call for heat. When it fails, the furnace runs through its ignition sequence, fails to light, and locks out — leaving the home without heat. Common symptoms include repeated ignition lockouts, a furnace that clicks but never fires, visible cracking or carbon on the element, and the control board flashing an ignition-failure fault code. Swapping in a fresh electrode is a fast, inexpensive repair that restores dependable ignition.

Specifications

Spec Value
Part Number 1179966
Type Ignitor Electrode
Brand ICP / Tempstar / Heil
Fits Model RGS300LEFA0AAAA
Application Gas Furnace Ignition
Fitment OEM Direct Replacement

Compatibility

This igniter electrode is the factory-specified replacement for the ICP Tempstar Heil RGS300LEFA0AAAA furnace. ICP-built furnaces ship under several badges — Tempstar, Heil, Comfortmaker, and others — so part 1179966 also services equivalent models across those brands. Confirm your unit's part number against the existing igniter before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker and shut off the gas. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace front service panel to expose the burner assembly.
  3. Document — Photograph the igniter's mounting position and wire routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw(s), and withdraw the old electrode without touching the element.
  5. Install — Seat the new igniter in the same position, reinstall the screws, and reconnect the harness per your photo. Handle by the base only.
  6. Test — Restore gas and power, then run a heat cycle to confirm the burners light promptly and hold flame.

Signs You Need a Replacement

  • Furnace ignites intermittently or locks out after failed attempts
  • No heat with the control board flashing an ignition-failure code
  • Visible cracks, carbon, or hot spots on the igniter element
  • Burners click or attempt to light but never establish flame

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee — if it doesn't fit, we make it right.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS300LEFA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS300LEFA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS300LEFA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.