Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS300HDFA0AAAA — Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS300HDFA0AAAA — Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM igniter electrode, ICP part number 1179966, is the ignition source for your RGS300HDFA0AAAA gas furnace. On a call for heat, the control board energizes the igniter so it glows or sparks to light the burner gas, then the flame sensor confirms ignition. Igniters are fragile and degrade with every heating cycle — the element grows brittle, develops hairline cracks, and eventually fails to reach ignition temperature or breaks entirely. A failed igniter is the single most common reason a gas furnace stops producing heat: the inducer and gas sequence may begin, but with no ignition the furnace locks out after a few attempts. Because igniters are inexpensive and wear-prone, many technicians replace them proactively during seasonal service to prevent a no-heat call on the coldest night.

Specifications

Spec Value
Part Number 1179966
Type Hot surface igniter electrode
Brand ICP / Tempstar / Heil
Supply Voltage 120V
Function Burner ignition on call for heat
Fitment OEM direct replacement

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil RGS300HDFA0AAAA gas furnace and equivalent RGS300-series units sold under Comfortmaker and Arcoaire. Confirm the part number and connector style match your existing igniter before installing.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, shut off the gas, and verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment door to reach the igniter at the burner assembly.
  3. Document — Photograph the igniter's mounting position and wire routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw(s), and carefully lift out the old igniter. Handle only by the ceramic base — never touch the element.
  5. Install — Position the new igniter without touching the element, secure the screws, and reconnect the harness per your photo.
  6. Test — Restore gas and power, call for heat, and watch the igniter glow and the burners light cleanly through a full cycle.

Signs You Need a Replacement

  • Furnace ignites no flame and locks out after several attempts.
  • Igniter does not glow or shows visible cracks/breaks.
  • Intermittent or delayed ignition with a small "poof" on light-off.
  • Igniter resistance reads open or out of spec on a meter.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS300HDFA0AAAA — Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS300HDFA0AAAA — Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS300HDFA0AAAA — Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart