Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS244HTAA0AAAA — OEM 1179966 | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS244HTAA0AAAA — OEM 1179966 | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM ignitor electrode (part #1179966) provides the ignition source for the ICP/Tempstar/Heil RGS244HTAA0AAAA gas furnace. On a call for heat, the control board energizes the igniter, which heats up to light the burners as the gas valve opens. The electrode is a brittle, high-temperature component that degrades with every ignition cycle. A cracked or worn igniter is one of the most common causes of no-heat calls — the furnace will go through its sequence, the inducer and gas valve will operate, but the burners never light and the unit locks out.

Specifications

Spec Value
OEM Part Number 1179966
Type Hot Surface Ignitor Electrode
Brand ICP / Tempstar / Heil
Fits Model RGS244HTAA0AAAA
Fitment OEM Direct Replacement

Compatibility

Direct factory replacement igniter for the ICP/Tempstar/Heil/Comfortmaker RGS244HTAA0AAAA furnace. Confirm the part number on your existing igniter matches 1179966 before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment door.
  3. Document — Photograph the igniter bracket position and wire routing before removing.
  4. Remove — Unplug the igniter connector and unscrew the mounting bracket; handle the old igniter by the ceramic base only.
  5. Install — Mount the new igniter without touching the element surface, then reconnect the harness.
  6. Test — Restore power, call for heat, and confirm the igniter glows and the burners light reliably.

Signs You Need a Replacement

  • Furnace runs its sequence but burners never ignite
  • Visible crack, chip, or break in the igniter element
  • Igniter glows dim, uneven, or not at all
  • Furnace locks out after several failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS244HTAA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS244HTAA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS244HTAA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online