Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS244HFFA0AAAA — OEM 1179966 Ignitor | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS244HFFA0AAAA — OEM 1179966 Ignitor | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

OEM igniter electrode (OEM part #1179966) for the ICP / Tempstar / Heil RGS244HFFA0AAAA gas furnace. The igniter is the heating element that glows on a call for heat and lights the burners during the ignition sequence. Igniters are a common wear item — the element is brittle and degrades with every heating cycle until it cracks or no longer reaches ignition temperature. When that happens the furnace runs the inducer and opens the gas valve but fails to light, then locks out on ignition. This OEM-spec igniter electrode restores reliable startup.

Specifications

Spec Value
OEM Part Number 1179966 (IGNITOR ELECTRODE)
Type Hot Surface Igniter Electrode
Brand ICP / Tempstar / Heil
Application Gas Furnace Burner Ignition
Fits Model RGS244HFFA0AAAA
Fit OEM Direct Replacement

Compatibility

Engineered for the ICP/Tempstar/Heil RGS244HFFA0AAAA gas furnace and related RGS244 units that use OEM igniter 1179966. Confirm the part number on your existing igniter before ordering.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker and verify zero voltage with a multimeter; let the igniter cool fully before handling.
  2. Access — Remove the furnace burner compartment service panel.
  3. Document — Photograph the igniter mounting position and wiring connector before removal.
  4. Remove — Unplug the igniter harness and unscrew the bracket; handle the new element by the ceramic base only — never touch the glow element.
  5. Install — Mount the new igniter in the exact factory position, ensuring correct spacing over the burner, and reconnect the harness.
  6. Test — Restore power and run a heat cycle; confirm the igniter glows brightly and lights the burners promptly with no lockout.

Signs You Need a Replacement

  • Furnace runs the inducer and opens gas but won't light (ignition lockout)
  • Visible crack, blistering, or break in the igniter element
  • Igniter glows weakly or not at all on a call for heat
  • Intermittent no-heat that worsens as the element ages

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS244HFFA0AAAA — OEM 1179966 Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS244HFFA0AAAA — OEM 1179966 Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS244HFFA0AAAA — OEM 1179966 Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera