This OEM igniter electrode (part number 1179966) provides the ignition source for the ICP Tempstar Heil RGS244HEFA0AAAA gas furnace. On a call for heat, the control board energizes the igniter, which heats up and lights the gas at the burners. Igniters are brittle and degrade with every heating cycle, making them one of the most common no-heat failures. Typical symptoms are a furnace that goes through its sequence but never lights, a glowing element that produces no flame, repeated lockouts, or a cracked/broken igniter element. Installing the correct OEM electrode restores reliable, on-demand ignition.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Igniter Electrode
Brand ICP / Tempstar / Heil
Supply Voltage 120V
Fits Model RGS244HEFA0AAAA
Fitment OEM direct replacement

Compatibility

Engineered for the ICP-family RGS244HEFA0AAAA sold under ICP, Tempstar, Heil, Comfortmaker, and Arcoaire. Verify the part number on your existing igniter matches 1179966 before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter before reaching into the burner area; never touch the ceramic element with bare fingers.
  2. Access — Remove the burner-compartment service panel to reach the igniter.
  3. Document — Photograph the igniter bracket position and wire routing before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw(s), then carefully withdraw the old electrode.
  5. Install — Mount the new igniter without touching the element, align it to the burner per your photo, and reconnect the harness.
  6. Test — Restore power, call for heat, and confirm the igniter glows and the burners light within the normal sequence.

Signs You Need a Replacement

  • Furnace runs its sequence but never lights (no-heat).
  • Igniter glows but the gas fails to ignite, then locks out.
  • Visible cracks, breaks, or white blistering on the ceramic element.
  • Repeated ignition lockouts requiring power resets to clear.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS244HEFA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS244HEFA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS244HEFA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online