Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS244HEAA0AAAA — OEM 1179966 | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS244HEAA0AAAA — OEM 1179966 | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM ICP igniter electrode (part #1179966) ignites the burner gas on a call for heat in your RGS244HEAA0AAAA furnace. The electrode creates the ignition source at the burner and, depending on the system, also serves the flame-sensing function that proves the burner has lit. A cracked ceramic, eroded electrode tip, or carbon-fouled sensor causes ignition lockouts, delayed ignition, or short-cycling on flame failure. Replacing it with the correct OEM electrode restores fast, reliable light-off and proper flame proving.

Specifications

Spec Value
Part Number 1179966
Type Ignitor / Ignition Electrode
Brand ICP (Tempstar / Heil)
Application Gas Furnace Burner Ignition
Fit OEM Replacement

Compatibility

Direct-fit replacement for the ICP / Tempstar / Heil RGS244HEAA0AAAA gas furnace. ICP uses common ignition components across its Heil, Tempstar, Comfortmaker, and Arcoaire brands, so this electrode may fit related models — confirm part number 1179966 against your unit before installing.

Installation Guide

  1. Safety First — Disconnect power and shut off the gas, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the electrode bracket position and wiring before removal.
  4. Remove — Disconnect the ignition lead, unfasten the mounting screw(s), and lift the old electrode out — handle ceramic carefully.
  5. Install — Mount the new electrode at the correct gap/position and reconnect the lead per your photo.
  6. Test — Restore gas and power, then run a heat cycle to confirm reliable ignition and flame proving.

Signs You Need a Replacement

  • Furnace locks out on ignition failure
  • Delayed ignition or a noticeable gas smell at light-off
  • Cracked ceramic insulator or visibly eroded electrode tip
  • Short-cycling on flame-sense / flame-failure faults

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS244HEAA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS244HEAA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS244HEAA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online