Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS243SSEA0AAAA — Direct-Spark Ignitor | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS243SSEA0AAAA — Direct-Spark Ignitor | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM ICP igniter electrode (part number 1179966) is the ignition component responsible for lighting the burners in your ICP Tempstar/Heil RGS243SSEA0AAAA gas furnace. When the thermostat calls for heat, the control board energizes this electrode to create the spark or hot surface needed to ignite the gas at the burner assembly. A failed or cracked electrode is one of the most common causes of a furnace that runs the inducer and gas valve but never produces heat. Typical failure symptoms include no ignition on a call for heat, repeated ignition lockouts, a furnace that short-cycles after several failed light attempts, or visible cracks and carbon buildup on the ceramic insulator.

Specifications

Spec Value
Part Number 1179966
Description Ignitor Electrode
Type Direct-Spark / Ignition Electrode
Brand ICP (Tempstar / Heil)
Fits Model RGS243SSEA0AAAA
Application Gas Furnace Burner Ignition
Fit OEM Direct Replacement

Compatibility

Engineered as a direct OEM replacement for the ICP Tempstar Heil RGS243SSEA0AAAA gas furnace and other ICP-family units that share this burner and ignition assembly. Always confirm your existing part number (1179966) and verify the electrode mounting bracket matches before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect electrical power at the furnace switch and breaker. Verify zero voltage with a multimeter before touching any wiring.
  2. Access — Remove the furnace blower/burner service panel to expose the burner assembly.
  3. Document — Photograph the electrode wire routing and bracket position before removing anything.
  4. Remove — Disconnect the ignition lead and remove the screw(s) securing the old electrode bracket; lift the electrode clear of the burner.
  5. Install — Mount the new electrode, setting the gap to factory spec, and reconnect the ignition lead per your photo.
  6. Test — Restore gas and power, run a heat cycle, and confirm clean, immediate ignition with no lockouts.

Signs You Need a Replacement

  • Furnace runs inducer and gas valve but never lights
  • Repeated ignition lockouts or flashing control-board error codes
  • Cracked ceramic insulator or carbon/corrosion on the electrode tip
  • Delayed ignition with a noticeable "whoosh" or rollout on startup

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS243SSEA0AAAA — Direct-Spark Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS243SSEA0AAAA — Direct-Spark Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS243SSEA0AAAA — Direct-Spark Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online