Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS243LFFA0AAAA — Furnace Ignition | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS243LFFA0AAAA — Furnace Ignition | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM igniter electrode (part number 1179966) is the ignition source for the ICP / Tempstar / Heil RGS243LFFA0AAAA gas furnace. On each heat call the control board sends voltage to the igniter, which glows red-hot and lights the gas at the burners. Igniters are a common wear item — repeated heat cycling makes the element brittle until it cracks or fails to reach temperature. When that happens the furnace tries to ignite, fails, and locks out, leaving the home without heat.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Igniter Electrode
Brand ICP / Tempstar / Heil
Function Burner Ignition
Application Gas Furnace
Fitment OEM Replacement

Compatibility

A direct OEM fit for the ICP RGS243LFFA0AAAA and equivalent Tempstar, Heil, Comfortmaker, and Carrier-family gas furnaces using this igniter. Confirm the mounting bracket and connector match your existing igniter before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker and verify zero voltage with a multimeter. Shut off the gas supply.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position, bracket, and wire routing before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw(s). Handle the old element by the ceramic base only.
  5. Install — Mount the new igniter without touching the element with bare fingers, then reconnect per your photo.
  6. Test — Restore gas and power, start a heat cycle, and confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace clicks and tries to start but never lights.
  • Igniter does not glow or glows only faintly.
  • Visible crack or break in the igniter element.
  • Furnace locks out after repeated failed ignition attempts.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS243LFFA0AAAA — Furnace Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS243LFFA0AAAA — Furnace Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS243LFFA0AAAA — Furnace Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online