This OEM igniter electrode (part 1179966) for the ICP/Tempstar/Heil RGS243HTFA0AAAA gas furnace heats up to light the burners at the start of every heat cycle. The igniter is one of the most common furnace wear items — its element becomes brittle with thousands of heat-up cycles and eventually cracks, leaving you with a furnace that runs the inducer and gas valve but never produces flame, then locks out. Oil from bare-handed handling can also create hot spots that shorten its life. This genuine OEM electrode matches the original's resistance, mounting position, and gas-train alignment for fast, dependable ignition.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Igniter Electrode
Brand ICP (Tempstar / Heil)
Supply Voltage 120V
Application Gas Furnace Burner Ignition
Fit OEM Replacement

Compatibility

Designed for the ICP/Tempstar/Heil RGS243HTFA0AAAA gas furnace and other RGS-series furnaces using igniter 1179966. Confirm the part number and connector style on your existing igniter before ordering.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter; the igniter operates on line voltage.
  2. Access — Remove the burner compartment door.
  3. Document — Photograph the igniter's bracket position and wire routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and carefully withdraw the old electrode without touching the new element.
  5. Install — Mount the new igniter by its bracket (handle by the ceramic base only) and reconnect the harness.
  6. Test — Restore power, call for heat, and confirm the igniter glows and the burners light within the trial-for-ignition window.

Signs You Need a Replacement

  • No glow when the furnace calls for heat
  • Visible crack or break in the igniter element
  • Furnace locks out after the inducer runs but no flame appears
  • Repeated ignition failures or delayed lighting

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS243HTFA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS243HTFA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS243HTFA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online