This is the OEM igniter electrode (OEM part #1179966) for the ICP / Tempstar / Heil RGS243HDAA0AAAA gas furnace. The igniter is the component that heats up and lights the burners at the start of every heat cycle. Igniters are brittle and degrade over time from repeated thermal cycling — micro-cracks, carbon buildup, or a broken element are extremely common no-heat causes. When the igniter fails, the furnace runs its inducer and opens the gas valve but never lights, then locks out on a failed-ignition fault. Replacing the igniter with the correct OEM electrode restores dependable, on-the-first-try burner light-off. Handle the new igniter only by its ceramic base — skin oils can create hot spots that shorten its life.

Specifications

Spec Value
OEM Part Number 1179966
Description Ignitor Electrode
Type Igniter Electrode (Hot Surface)
Brand ICP / Tempstar / Heil
Application Gas Furnace Burner Ignition
Fit OEM Direct Replacement

Compatibility

Direct OEM fit for the ICP Tempstar Heil RGS243HDAA0AAAA furnace and matching ICP-family units (Tempstar, Heil, Comfortmaker) that specify igniter OEM #1179966. Confirm the part number and connector style on your existing igniter before ordering.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker; verify zero voltage at the igniter connector with a multimeter, and shut off the gas supply.
  2. Access — Remove the burner-compartment service panel to reach the igniter at the burner assembly.
  3. Document — Photograph the igniter's position and bracket orientation before removal.
  4. Remove — Unplug the igniter harness connector, remove the mounting screw(s), and carefully withdraw the old igniter without touching the element.
  5. Install — Mount the new igniter in the factory position (handling it only by the ceramic base) and reconnect the harness per your photo.
  6. Test — Restore gas and power, start a heat call, and confirm the igniter glows and the burners light on the first attempt.

Signs You Need a Replacement

  • Furnace locks out on failed ignition — inducer runs but burners never light.
  • Igniter does not glow, or glows weakly/unevenly.
  • Visible cracks, breaks, or heavy carbon on the igniter element.
  • Delayed ignition with a noticeable "whoomp" when the burners finally catch.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS243HDAA0AAAA — OEM Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS243HDAA0AAAA — OEM Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS243HDAA0AAAA — OEM Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.