Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS240STFA0AAAA – OEM 1179966 | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS240STFA0AAAA – OEM 1179966 | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM igniter electrode (part number 1179966) fits the ICP / Tempstar / Heil RGS240STFA0AAAA furnace. The hot surface igniter glows to a high temperature when energized by the control board, lighting the burner gas at the start of every heat cycle. Igniters are a wear item: the element grows brittle with repeated thermal cycling and eventually cracks or fails open, leaving the furnace unable to light. Common symptoms include a furnace that goes through its inducer and gas-valve sequence but never lights, repeated ignition lockouts, or a visibly cracked or no-longer-glowing element. Installing a fresh OEM igniter restores reliable, on-demand ignition and eliminates no-heat lockout calls.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Igniter Electrode
Brand ICP / Tempstar / Heil
Application Gas Furnace Burner Ignition
Fits Model RGS240STFA0AAAA
Fit Type OEM Replacement

Compatibility

Designed for the ICP / Tempstar / Heil RGS240STFA0AAAA furnace and related RGS-series units originally equipped with the 1179966 igniter. Verify the igniter's mounting bracket and connector style against your existing part before ordering.

Installation Guide

  1. Safety First – Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access – Remove the furnace burner-compartment service panel.
  3. Document – Photograph the igniter's mounting position and wire routing before disconnecting.
  4. Remove – Unplug the igniter connector, remove the mounting screw, and carefully withdraw the brittle element without touching the ceramic.
  5. Install – Mount the new igniter by its bracket only, never touching the element surface, and reconnect the lead per your photo.
  6. Test – Restore power, call for heat, and confirm the igniter glows and the burners light cleanly.

Signs You Need a Replacement

  • Furnace sequences but the burners never light.
  • Repeated ignition lockouts requiring a reset.
  • Igniter element is visibly cracked or no longer glows.
  • Intermittent ignition, especially on cold starts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS240STFA0AAAA – OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS240STFA0AAAA – OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS240STFA0AAAA – OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online