Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS240SEBB0AGAA — OEM 1179966 | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS240SEBB0AGAA — OEM 1179966 | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

The 1179966 igniter electrode is the OEM ignition component for ICP/Tempstar/Heil RGS240SEBB0AGAA gas furnaces. It generates the spark or hot surface needed to ignite the gas burners on each heating cycle. When this part fails, the furnace will draft and call for heat but never light, often locking out after several failed ignition attempts. A cracked ceramic insulator, carbon buildup, or a hairline break in the element are the most common failure points. Replacing the igniter restores reliable, on-demand ignition.

Specifications

Spec Value
Part Number 1179966
Type Igniter Electrode
Brand ICP / Tempstar / Heil
Application Gas Furnace Ignition
Fitment OEM Direct-Fit

Compatibility

Engineered for the ICP/Tempstar/Heil RGS240SEBB0AGAA gas furnace and other models in the same series that share this ignition assembly. Always confirm against your furnace's parts diagram.

Installation Guide

  1. Safety First — Disconnect power and shut off the gas supply; verify zero voltage with a multimeter.
  2. Access — Remove the furnace service panel(s).
  3. Document — Photo all wires and the igniter bracket position before disconnecting.
  4. Remove — Unplug the igniter lead and remove the mounting screw(s); handle the ceramic body only, never the element.
  5. Install — Mount the new igniter at the correct gap/position and reconnect the lead per your photo.
  6. Test — Restore gas and power, then run a full heat cycle to confirm clean ignition.

Signs You Need a Replacement

  • Furnace clicks and drafts but burners never light
  • Visible cracks or carbon scoring on the ceramic
  • Repeated ignition lockouts on the control board
  • No glow or spark at the igniter on a heat call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS240SEBB0AGAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS240SEBB0AGAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS240SEBB0AGAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online