The ICP igniter electrode (OEM part 1179966) lights the burners in your RGS240LRFA0AAAA gas furnace. On each heat call, the control board energizes this igniter to ignite gas at the burner assembly. A cracked or burned-out igniter is one of the most common no-heat failures — the blower may run while the burners never light. This genuine OEM-spec replacement matches the original resistance and mounting so ignition stays reliable cycle after cycle.

Specifications

Spec Value
Part Number 1179966
Description Ignitor Electrode
Type Igniter / Ignition Electrode
Brand ICP (Tempstar / Heil)
Application Gas Furnace Burner Ignition
Fitment OEM Direct Replacement

Compatibility

Designed for the ICP / Tempstar / Heil RGS240LRFA0AAAA gas furnace and RGS240-family equipment using OEM part 1179966. Verify your existing part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; shut off the gas supply and verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position and wiring before disconnecting.
  4. Remove — Disconnect the igniter lead, remove the mounting screw(s), and withdraw the old electrode without touching the ceramic element.
  5. Install — Mount the new igniter, handling it only by the base, and reconnect the lead per your photo.
  6. Test — Restore gas and power, then run a full heat cycle to confirm proper ignition and a stable flame.

Signs You Need a Replacement

  • Furnace blower runs but burners never light (no heat).
  • Visible cracks, chips, or white/blistered spots on the ceramic element.
  • Repeated ignition lockouts or multiple failed ignition attempts.
  • Delayed ignition with a gas smell or burner rollout at startup.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS240LRFA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS240LRFA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS240LRFA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.