Overview

This OEM igniter electrode (part number 1179966) is the hot surface igniter for the ICP / Tempstar / Heil RGS240LREA0AAAA gas furnace. On a call for heat the control board sends voltage to the igniter, which glows red-hot and lights the gas at the burners. Hot surface igniters are brittle and degrade over time — a cracked or worn igniter is one of the most common causes of no-heat calls. When it fails, the furnace inducer and gas valve may cycle but the burners never light, often ending in ignition lockout. Replacing the igniter with the correct OEM electrode restores fast, reliable ignition.

Specifications

Spec Value
Part Number 1179966 (IGNITOR ELECTRODE)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Fits Model RGS240LREA0AAAA
Application Gas Furnace
Fit OEM Direct Replacement

Compatibility

Direct-fit replacement for the ICP / Tempstar / Heil RGS240LREA0AAAA gas furnace. Verify the part number on your existing igniter matches 1179966 before installing.

Installation Guide

  1. Safety First — Disconnect power and shut off the gas; verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter position and wire routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw(s), and carefully withdraw the old igniter without touching the ceramic.
  5. Install — Mount the new igniter — handle only by the ceramic base, never the element — and reconnect the lead per your photo.
  6. Test — Restore gas and power, run a heat cycle, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace will not light and goes into ignition lockout.
  • Igniter does not glow on a call for heat.
  • Visible cracks, chips, or hot spots on the element.
  • Igniter reads open or out-of-spec resistance on a meter.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS240LREA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS240LREA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS240LREA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online