Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS240LDAA0AAAA — OEM | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS240LDAA0AAAA — OEM | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM igniter electrode (part number 1179966) provides the ignition source for the ICP/Tempstar/Heil model RGS240LDAA0AAAA furnace. On each heat call, the control board energizes the igniter, which heats to the temperature required to light the burner gas. Because the electrode is brittle and endures repeated thermal cycling, it is one of the most common wear items in a gas furnace. A cracked or worn igniter is a leading cause of no-heat conditions where the inducer and gas valve operate normally but the burners never light.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Igniter Electrode
Brand ICP / Tempstar / Heil
Application Gas Furnace Ignition
Fit OEM Direct Replacement

Compatibility

Engineered as a direct OEM fit for the ICP/Tempstar/Heil RGS240LDAA0AAAA furnace. Compatible across ICP-family furnaces that share the same ignition electrode assembly. Confirm the mounting bracket orientation and connector style match your existing igniter before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect furnace power, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position and wiring before disconnecting.
  4. Remove — Unplug the igniter connector and unscrew the mounting bracket. Handle the old igniter by the base, never the ceramic.
  5. Install — Mount the new igniter without touching the element with bare fingers, then reconnect the harness per your photo.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and the burners light on the first attempt.

Signs You Need a Replacement

  • Furnace runs the ignition sequence but burners never light (no-heat).
  • Visible cracks, chips, or hot spots on the element.
  • Igniter glows weakly or not at all during a heat call.
  • Repeated lockouts after several failed ignition attempts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS240LDAA0AAAA — OEM | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS240LDAA0AAAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS240LDAA0AAAA — OEM | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online