Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS240HTFA0AAAA — OEM 1179966 | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS240HTFA0AAAA — OEM 1179966 | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM igniter electrode (part number 1179966) for the ICP/Tempstar/Heil RGS240HTFA0AAAA gas furnace. The igniter electrode heats to a high temperature on each call for heat to light the burner gas as it flows across the manifold. Because the element is repeatedly heated and cooled, it is one of the most common wear items in a gas furnace — it eventually cracks, develops hot spots, or breaks entirely, leaving the furnace unable to ignite. Typical symptoms are a furnace that clicks and runs the inducer but never lights, or one that locks out after several failed ignition attempts. Installing a fresh OEM electrode restores reliable, fast ignition.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Igniter Electrode
Brand ICP / Tempstar / Heil
Fits Model RGS240HTFA0AAAA
Fit OEM Replacement
Application Gas Furnace Ignition

Compatibility

Direct-fit replacement for the ICP/Tempstar/Heil RGS240HTFA0AAAA furnace. This Comfortmaker-family igniter electrode is shared across several related RGS-series furnaces — confirm your existing part number before ordering.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter before servicing.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter position and wire routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw(s), and withdraw the fragile element carefully.
  5. Install — Mount the new 1179966 electrode without touching the hot-surface element by hand, then reconnect the lead per your photo.
  6. Test — Restore power, call for heat, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace runs the inducer but never lights the burners
  • Visible crack, blistering, or break in the igniter element
  • Repeated ignition lockouts on a call for heat
  • No glow when the igniter is energized

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS240HTFA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS240HTFA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS240HTFA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online