Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS240HTAA0AAAA - OEM | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS240HTAA0AAAA - OEM | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM igniter electrode (part number 1179966) is the hot surface ignition component for your ICP / Tempstar / Heil RGS240HTAA0AAAA gas furnace. On each call for heat the control board sends voltage to the igniter, which glows red-hot to light the burner gas. Hot surface igniters are a normal wear item - the element becomes brittle with thousands of heat cycles and eventually cracks or burns open, leaving the furnace unable to light. A failed igniter is one of the most common causes of no-heat calls. Replacing it with the exact OEM electrode restores fast, reliable ignition without the misfires or lockouts of a worn element.

Specifications

Spec Value
Part Number 1179966
Type Hot surface igniter electrode
Brand ICP / Tempstar / Heil
Function Ignites burner gas on heat call
Application Gas furnace ignition
Fitment OEM exact replacement

Compatibility

Engineered as the factory hot surface igniter for the ICP / Tempstar / Heil RGS240HTAA0AAAA gas furnace and shared across related ICP-family furnace platforms using the same ignition system. Confirm part number 1179966 and the bracket/connector style on your existing igniter before ordering.

Installation Guide

  1. Safety First - Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter; shut off the gas supply.
  2. Access - Remove the furnace burner/service panel to reach the igniter.
  3. Document - Photograph the igniter mounting and wire connector before disconnecting.
  4. Remove - Unplug the connector and unscrew the old igniter, handling it only by the ceramic base - never touch the element.
  5. Install - Mount the new OEM igniter (touch only the base) and reconnect the plug per your photo.
  6. Test - Restore gas and power, then watch a full ignition cycle to confirm a clean light.

Signs You Need a Replacement

  • Furnace blows cold air or fails to light on a heat call.
  • Igniter does not glow, or glows weakly/unevenly.
  • Visible cracks or breaks in the igniter element.
  • Repeated ignition lockouts after several failed attempts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS240HTAA0AAAA - OEM | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS240HTAA0AAAA - OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS240HTAA0AAAA - OEM | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart