Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS240HEAA0AAAA — OEM 1179966 | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS240HEAA0AAAA — OEM 1179966 | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM igniter electrode (part number 1179966) for the ICP/Tempstar/Heil RGS240HEAA0AAAA gas furnace. The igniter electrode heats to ignition temperature when the control board energizes it at the start of a heat cycle, lighting the gas at the burners. Igniters are brittle and wear out from thermal cycling; a cracked or open igniter is one of the most common causes of furnace no-heat calls. Symptoms include the furnace going through its sequence but never lighting, a board lockout after several failed ignition attempts, or no visible glow at the igniter. Replacing the igniter with the correct OEM part restores fast, reliable ignition.

Specifications

Spec Value
OEM Part Number 1179966
Type Hot Surface Igniter Electrode
Brand ICP / Tempstar / Heil
Application Furnace burner ignition
Fit OEM Replacement

Compatibility

Built for the ICP/Tempstar/Heil RGS240HEAA0AAAA gas furnace and related RGS-series units. Confirm the igniter part number and mounting bracket style before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment door.
  3. Document — Photograph the igniter bracket position and wire routing before disconnecting.
  4. Remove — Unplug the igniter connector and unscrew the bracket; handle the new igniter only by the ceramic base, never the element.
  5. Install — Mount the new igniter, reconnect the connector per your photo, and confirm proper gap to the burner.
  6. Test — Restore power and run a heat cycle to verify the igniter glows and lights the burners.

Signs You Need a Replacement

  • Furnace runs its sequence but never lights
  • No glow visible at the igniter during ignition
  • Repeated ignition-failure lockouts on the control board
  • Visible cracks or breaks in the igniter element

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS240HEAA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS240HEAA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS240HEAA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online