Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS214LEAA0AAAA — OEM | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS214LEAA0AAAA — OEM | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM igniter electrode (part #1179966) is the ignition source for the ICP / Tempstar / Heil RGS214LEAA0AAAA furnace. On each heat call, the control board energizes the igniter so it glows hot and lights the burner gas. Over time the fragile element develops hairline cracks, carbon buildup, or simply burns out from thousands of heating cycles. A failed igniter is one of the most common causes of no-heat calls: the inducer runs and the gas valve clicks, but the burners never light. Replacing a worn igniter restores fast, dependable ignition and prevents repeated lockouts.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Igniter Electrode
Brand ICP (Tempstar / Heil)
Application Gas Furnace Ignition

Compatibility

Direct OEM fit for the ICP/Tempstar/Heil RGS214LEAA0AAAA and related RGS214 series gas furnaces. Match the part number and mounting bracket to your existing igniter before installing. Handle the element only by the ceramic base — finger oils on the element shorten its life.

Installation Guide

  1. Safety First — Shut off gas and disconnect electrical power, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment door.
  3. Document — Photograph the igniter position, bracket, and wire routing before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw(s). Lift the old igniter out carefully, avoiding contact with the burners.
  5. Install — Mount the new igniter at the same depth and angle, handling it only by the ceramic base, then reconnect the plug.
  6. Test — Restore gas and power, start a heat cycle, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace runs the inducer and clicks the gas valve but burners never light
  • Visible cracks or breaks in the igniter element
  • Igniter glows weakly or not at all
  • Repeated ignition lockouts after 3 trial cycles

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS214LEAA0AAAA — OEM | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS214LEAA0AAAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS214LEAA0AAAA — OEM | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online