Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS214HDCW4BAAA | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS214HDCW4BAAA | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM ignitor electrode (part 1179966) is the hot surface ignition component for the ICP Tempstar Heil RGS214HDCW4BAAA gas furnace. On each heat call, the furnace control energizes the igniter, which heats to a glowing temperature to ignite the gas at the burner. Igniters are the most common furnace failure point because the heating element is brittle and degrades with every thermal cycle. Typical failure symptoms include no ignition, the furnace cycling on the limit, a visibly cracked element, or an igniter that no longer glows. Because the element is fragile, never touch its surface with bare fingers — skin oils create hot spots that shorten its life.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Igniter / Electrode
Brand ICP / Tempstar / Heil
Voltage 120V
Application Gas Furnace Ignition

Compatibility

Direct OEM fit for the ICP Tempstar Heil RGS214HDCW4BAAA furnace and related Comfortmaker/Heil gas furnaces using this burner assembly. Confirm the mounting bracket and connector match your existing igniter.

Installation Guide

  1. Safety First — Shut off gas and disconnect power, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner compartment door.
  3. Document — Photograph the igniter position and wiring before removal.
  4. Remove — Unplug the igniter connector and remove the mounting screw, handling the old igniter by its ceramic base only.
  5. Install — Mount the new igniter without touching the element, then reconnect the harness per your photo.
  6. Test — Restore gas and power and confirm the igniter glows and lights the burners.

Signs You Need a Replacement

  • Furnace blower runs but there is no heat or flame
  • Visibly cracked, chipped, or broken ceramic element
  • Igniter does not glow during a heat call
  • Repeated ignition lockouts on the control board

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS214HDCW4BAAA | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS214HDCW4BAAA | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS214HDCW4BAAA | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online