Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS214HDCB4BAAA — Furnace Ignition | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS214HDCB4BAAA — Furnace Ignition | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter electrode (part 1179966) is the ignition source for your ICP / Heil / Tempstar RGS214HDCB4BAAA gas furnace. On each call for heat the control board sends 120V to the igniter; its silicon-nitride/carbide element glows red-hot to ignite the gas at the burners. Igniters are the most common furnace failure point — the brittle element cracks from thermal cycling, contamination, or age, leaving you with no heat. A failed igniter typically produces a furnace that clicks and tries to light but never fires, or that locks out after several failed attempts. Replacing this fragile but inexpensive part restores reliable ignition and is one of the most frequent furnace repairs.

Specifications

Spec Value
OEM Part Number 1179966
Type Hot Surface Igniter / Ignitor Electrode
Brand ICP / Heil / Tempstar
Voltage 120V
Function Burner ignition
Fits Model RGS214HDCB4BAAA

Compatibility

Direct-fit replacement for the ICP / Heil / Tempstar RGS214HDCB4BAAA gas furnace and related ICP-built furnaces using the same igniter mount and 120V ignition circuit. Match the bracket and element style to your existing igniter before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner compartment door.
  3. Document — Photograph the igniter position and wiring before removal.
  4. Remove — Unplug the igniter connector and remove the mounting screw; handle the old element by the ceramic base only.
  5. Install — Mount the new igniter without touching the element (skin oils cause early failure), then reconnect the plug.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and the burners light on the first cycle.

Signs You Need a Replacement

  • Furnace tries to light but burners never ignite
  • No glow visible at the igniter during a heat call
  • Furnace locks out after several ignition attempts
  • Visible cracks or breaks in the igniter element

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS214HDCB4BAAA — Furnace Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS214HDCB4BAAA — Furnace Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS214HDCB4BAAA — Furnace Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online