Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS213LSAA0AAAA | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS213LSAA0AAAA | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter electrode (part number 1179966) is the component that lights the burners on the ICP/Tempstar/Heil RGS213LSAA0AAAA furnace. On a call for heat, the control board sends 120V to the igniter, which glows red-hot to ignite the gas as the valve opens. Igniters are brittle and wear out from repeated heating cycles. Typical failure symptoms include a furnace that runs the inducer and blower but never produces heat, no visible glow during the ignition sequence, a cracked or chipped igniter element, and short-cycling on ignition lockout.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Igniter Electrode
Brand ICP (Tempstar / Heil)
Voltage 120V
Application Gas Furnace Ignition
Fit OEM Replacement

Compatibility

A direct OEM fit for the ICP/Tempstar/Heil RGS213LSAA0AAAA gas furnace and compatible with ICP-family furnaces that use this igniter electrode assembly. Verify the mounting bracket orientation and connector style against your existing igniter before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect electrical power, then verify zero voltage at the igniter leads with a multimeter.
  2. Access — Remove the furnace burner compartment door to reach the igniter.
  3. Document — Photograph the igniter position, bracket, and wiring connector before removal.
  4. Remove — Unplug the igniter connector and remove the mounting screw; lift the old igniter out, handling only by the ceramic base — never touch the silicon-carbide element.
  5. Install — Set the new igniter so the element sits in the burner flame path, secure the bracket screw, and reconnect the plug.
  6. Test — Restore gas and power, then run a heat cycle and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace inducer and blower run but no heat is produced.
  • No glow visible during the ignition sequence.
  • Visible cracks or chips in the igniter element.
  • Furnace locks out after several failed ignition attempts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS213LSAA0AAAA | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS213LSAA0AAAA | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS213LSAA0AAAA | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online