Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS213LREA0AAAA — Direct Spark Ignitor | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS213LREA0AAAA — Direct Spark Ignitor | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM ignitor electrode (part number 1179966) for the ICP Tempstar Heil RGS213LREA0AAAA gas furnace. The igniter electrode is responsible for creating the ignition spark or surface heat that lights the burners during a call for heat. When the electrode degrades, cracks, or becomes contaminated with carbon, the furnace will fail to ignite, short-cycle, or lock out on ignition failure. Replacing the electrode restores reliable, on-demand ignition and prevents nuisance no-heat calls during the heating season.

Specifications

Spec Value
Part Number 1179966
Description Ignitor Electrode
Type Ignition Electrode
Brand ICP / Tempstar / Heil
Fit OEM Replacement
Application Gas Furnace Ignition

Compatibility

Engineered as a direct-fit replacement for the ICP Tempstar Heil RGS213LREA0AAAA gas furnace and other models in the RGS213 family that use OEM electrode 1179966. Always confirm the part number against your existing electrode before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, shut off the gas, and verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the electrode position, gap, and ignition wire routing before disconnecting.
  4. Remove — Disconnect the high-voltage ignition lead, remove the mounting screw(s), and lift out the old electrode and gasket.
  5. Install — Mount the new electrode with the correct gap, reattach the ignition lead, and seat the gasket per your photo.
  6. Test — Restore gas and power, then run a heat cycle to confirm clean, immediate ignition.

Signs You Need a Replacement

  • Furnace locks out on ignition failure or repeated retries
  • No spark or weak/erratic spark at the burners
  • Visible cracks, carbon buildup, or erosion on the electrode tip
  • Delayed ignition with a rollout or whoosh on startup

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS213LREA0AAAA — Direct Spark Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS213LREA0AAAA — Direct Spark Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS213LREA0AAAA — Direct Spark Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.