Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS213LFAA0AAAA — OEM 1179966 | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS213LFAA0AAAA — OEM 1179966 | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM igniter electrode (part number 1179966) for the ICP / Heil / Tempstar RGS213LFAA0AAAA gas furnace. The igniter is the component responsible for lighting the burners on every heat call. When 24V is applied during the ignition sequence, the element heats and ignites the gas at the main burner. A cracked, eroded, or open igniter is one of the most common causes of a furnace that clicks, sparks, or attempts to start but never produces heat. This electrode is a brittle ceramic-element part — handle it only by the ceramic base and never touch the element with bare fingers, as skin oils shorten its life.

Specifications

Spec Value
Part Number 1179966
Description Ignitor Electrode
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Fits Model RGS213LFAA0AAAA
Fit OEM Direct Replacement

Compatibility

Engineered as a direct-fit replacement for the ICP/Heil/Tempstar RGS213LFAA0AAAA furnace and other Comfortmaker-family units that originally shipped with OEM part 1179966. Always confirm your existing igniter part number before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect power at the furnace switch and breaker. Verify zero voltage with a multimeter.
  2. Access — Remove the lower burner-compartment service panel.
  3. Document — Photograph the igniter bracket and wire routing before disconnecting.
  4. Remove — Disconnect the igniter plug, remove the mounting screw, and carefully withdraw the old electrode without bumping the burners.
  5. Install — Mount the new igniter, holding it only by the ceramic base, and reconnect the plug exactly as photographed.
  6. Test — Restore gas and power, then run a heat cycle and confirm the igniter glows and the burners light cleanly.

Signs You Need a Replacement

  • Furnace tries to ignite but never lights the burners.
  • Visible cracks, blistering, or breaks in the igniter element.
  • Igniter no longer glows during the ignition sequence.
  • Intermittent no-heat calls that resolve after a reset, then return.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS213LFAA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS213LFAA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS213LFAA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online