Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS213HREA0AAAA — OEM 1179966 | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS213HREA0AAAA — OEM 1179966 | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine ICP/Tempstar/Heil OEM igniter electrode (part 1179966) is the ignition component that lights the burners on the RGS213HREA0AAAA gas furnace. On a call for heat, the furnace control energizes the igniter, which heats or sparks at the burner to ignite the gas. The electrode is positioned precisely in the burner flame path, so a cracked element, eroded tip, or hairline fracture is one of the most common reasons a furnace fails to light, locks out after several ignition attempts, or short-cycles on a flame fault. The igniter is a wear item and should be handled only by its ceramic base — skin oils and physical contact with the element shorten its life.

Specifications

Spec Value
Part Number 1179966
Type Igniter Electrode
Brand ICP / Tempstar / Heil
Application Gas Furnace Ignition
Fit OEM

Compatibility

Designed for the ICP/Tempstar/Heil RGS213HREA0AAAA furnace and other ICP-family models that use the 1179966 ignition electrode. Verify the part number and mounting/bracket orientation against your existing igniter before ordering.

Installation Guide

  1. Safety First — Turn off the gas, disconnect power at the switch and breaker, and verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter's wiring, bracket, and position relative to the burner before removal.
  4. Remove — Unplug the igniter lead and remove the mounting screw(s), then withdraw the old electrode without touching the element.
  5. Install — Mount the new 1179966 igniter handling it by the ceramic base only, reconnect the lead, and confirm correct burner alignment.
  6. Test — Restore gas and power, then run a heat cycle and verify reliable ignition.

Signs You Need a Replacement

  • Furnace fails to light or locks out after repeated ignition attempts.
  • Visible crack, fracture, or eroded tip on the igniter element.
  • No glow/spark observed during the ignition sequence.
  • Short-cycling with an ignition or flame-fault code.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS213HREA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS213HREA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS213HREA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online