Overview

This is the genuine OEM ignitor electrode (part 1179966) for the ICP / Tempstar / Heil RGS213HRAA0AAAA gas furnace. The hot surface igniter is the element the control board energizes at the start of every heat cycle; it heats to a glowing temperature and lights the gas as the valve opens. It is the single most-replaced furnace part because the brittle silicon-carbide/nitride element degrades with every ignition cycle and eventually cracks or loses continuity.

When the igniter fails, the furnace typically goes through its full sequence — inducer runs, board calls for ignition — but no flame appears, then it locks out. You may see no glow at all, a weak or partial glow, or the furnace lighting only after several retries. Because the element is fragile and oils from bare fingers can shorten its life, always handle the new igniter by its ceramic base only.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Igniter Electrode
Brand ICP / Tempstar / Heil
Voltage 120V
Fits Model RGS213HRAA0AAAA
Application Gas furnace ignition

Compatibility

Direct-fit for the ICP RGS213HRAA0AAAA and shared across many Tempstar, Heil, and Comfortmaker furnaces using this igniter electrode. Confirm the mounting bracket and connector match your original before ordering.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, shut off the gas, and verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position and wire routing before removing it.
  4. Remove — Unplug the igniter connector and remove the mounting screw(s); handle only by the ceramic base.
  5. Install — Mount the new igniter (touching only the base), align it to the burner, and reconnect the plug.
  6. Test — Restore gas and power, start a heat cycle, and confirm the element glows and lights the burners.

Signs You Need a Replacement

  • Furnace sequences but produces no flame, then locks out
  • No glow or only a weak/partial glow at the igniter
  • Visible cracks or chips in the igniter element
  • Furnace lights only after multiple ignition retries

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS213HRAA0AAAA | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS213HRAA0AAAA | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS213HRAA0AAAA | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online