Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS210LFEA0AAAA — Direct Ignition | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS210LFEA0AAAA — Direct Ignition | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM igniter electrode (part #1179966) is the ignition component for the ICP/Heil/Tempstar RGS210LFEA0AAAA gas furnace. Each time the furnace receives a call for heat, the control board energizes this electrode to spark and light the main burner. The electrode tip and ceramic insulator face repeated high-heat cycles, so over time the metal erodes, the ceramic cracks, or the gap shifts out of tolerance — leaving the furnace unable to ignite consistently. Installing a fresh OEM electrode restores fast, dependable ignition and clears no-heat and short-cycle faults. This is a genuine OEM replacement made to the exact gap, mounting, and high-temperature specification of the furnace.

Specifications

Spec Value
Part Number 1179966
Part Type Igniter Electrode
Brand ICP / Heil / Tempstar
Ignition Type Direct / Spark Electrode
Fits Model RGS210LFEA0AAAA
Fit OEM

Compatibility

Engineered for the ICP family RGS210LFEA0AAAA gas furnace and sold under the Heil, Tempstar, and Comfortmaker labels. Confirm the part number on your existing electrode and match the furnace model number before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect electrical power. Verify zero voltage at the control board with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the electrode wire routing and mounting position before disconnecting.
  4. Remove — Disconnect the ignition lead, remove the mounting screw(s), and lift the old electrode away from the burner.
  5. Install — Mount the new electrode at the factory gap, reconnect the ignition lead per your photo, and confirm the tip aligns with the burner flame path.
  6. Test — Restore gas and power, run a heat cycle, and confirm clean, immediate ignition.

Signs You Need a Replacement

  • Furnace sparks or clicks but the burner fails to light
  • Intermittent no-heat calls or repeated ignition retries before lockout
  • Cracked ceramic insulator or eroded electrode tip
  • Carbon buildup or corrosion on the electrode rod

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS210LFEA0AAAA — Direct Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS210LFEA0AAAA — Direct Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS210LFEA0AAAA — Direct Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online