This OEM ignitor electrode (part #1179966) is the ignition source for the ICP Tempstar/Heil RGS210HTEA0AAAA gas furnace. On a heat call, the control board energizes the igniter, which heats to glowing temperature to light the burners. Igniters are a normal wear item — the heating element is brittle and degrades with every cycle, eventually cracking or developing a hairline fracture that prevents it from reaching ignition temperature. The result is a furnace that clicks, runs the inducer, but never lights, often locking out after several failed attempts. This genuine OEM electrode delivers the correct resistance and reach for reliable, on-spec ignition.

Specifications

Spec Value
Part Number 1179966
Description IGNITOR ELECTRODE
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Fits Model RGS210HTEA0AAAA
Fitment OEM Direct Replacement

Compatibility

Engineered for the ICP Tempstar Heil RGS210HTEA0AAAA gas furnace. Confirm your existing igniter part number and mounting style before ordering for an exact fit.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter's position, orientation, and wire connector before removal.
  4. Remove — Unplug the igniter harness and remove the mounting screw(s); handle the old element only by its ceramic base. Never touch the new element's surface with bare fingers.
  5. Install — Mount the new electrode in the same position and reconnect the harness.
  6. Test — Restore power, start a heat cycle, and confirm the igniter glows and lights the burners promptly.

Signs You Need a Replacement

  • Furnace inducer runs but burners never light
  • Igniter does not glow or glows weakly
  • Visible cracks or breaks in the ignition element
  • Furnace locks out after repeated failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS210HTEA0AAAA — OEM Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS210HTEA0AAAA — OEM Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS210HTEA0AAAA — OEM Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.