Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS210HTCA0AAAA — OEM 1179966 | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS210HTCA0AAAA — OEM 1179966 | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface igniter electrode, ICP part 1179966, is the ignition source for the ICP / Tempstar / Heil RGS210HTCA0AAAA gas furnace. On a call for heat the control board sends voltage to the igniter, which glows red-hot and lights the gas at the burners. Hot surface igniters are a normal wear item — the brittle silicon-carbide or nitride element degrades with every heating cycle and eventually cracks or loses the ability to reach ignition temperature. When the igniter fails, the furnace draws and purges but never lights, then locks out, leaving you with no heat. Because the element is fragile, even touching its surface with bare fingers can shorten its life, so it is one of the most frequently replaced furnace parts.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Igniter Electrode
Brand ICP / Tempstar / Heil
Function Burner Ignition
Fitment OEM Replacement

Compatibility

Directly fits the ICP/Tempstar/Heil RGS210HTCA0AAAA furnace. Always replace with the OEM-spec igniter and connector for this model — universal igniters require an adapter harness and correct mounting bracket to seat properly in the burner flame path.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter and shut the gas if servicing the burner area.
  2. Access — Remove the furnace burner/control access panel.
  3. Document — Photograph the igniter bracket position and connector routing.
  4. Remove — Unplug the igniter connector and remove the mounting screw; handle the old element by its ceramic base only.
  5. Install — Mount the new igniter without touching the element, seat it in the correct flame position, and reconnect.
  6. Test — Restore power and confirm the igniter glows and lights the burners on a heat call.

Signs You Need a Replacement

  • Furnace tries to start, purges, then locks out with no flame.
  • Igniter shows a visible crack or no longer glows.
  • No heat after repeated ignition retries.
  • Igniter glows weakly or unevenly.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS210HTCA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS210HTCA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS210HTCA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online