Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS210HECA0AAAA | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS210HECA0AAAA | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM igniter electrode, P/N 1179966, ignites the burners in ICP / Heil / Tempstar gas furnaces. On a call for heat the control board energizes the igniter, which heats up (or sparks, depending on configuration) to light the gas at the burner. Igniters are brittle and degrade with every heat cycle; a cracked or worn electrode is one of the most common reasons a furnace blows cold air or locks out on ignition failure. Installing a fresh OEM electrode restores reliable, on-demand ignition.

Specifications

Spec Value
Part Number 1179966
Type Igniter Electrode (Hot Surface)
Brand ICP / Heil / Tempstar
Application Gas Furnace Ignition
Fitment OEM

Compatibility

Direct OEM replacement for ICP, Heil and Tempstar model RGS210HECA0AAAA and furnaces originally equipped with igniter electrode 1179966. Confirm against your furnace's parts diagram before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect power, then verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter mounting and wiring before removal.
  4. Remove — Unplug the igniter lead and unscrew the electrode; handle it only by the ceramic base, never the element.
  5. Install — Mount the new igniter without touching the element and reconnect the lead per your photo.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm the burners light.

Signs You Need a Replacement

  • Furnace blows cold air or won't light
  • Igniter doesn't glow or spark on a heat call
  • Visible cracks or chips in the igniter element
  • Furnace locks out on repeated ignition-failure faults

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS210HECA0AAAA | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS210HECA0AAAA | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS210HECA0AAAA | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online