Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS210HDEA0AAAA — OEM 1179966 | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS210HDEA0AAAA — OEM 1179966 | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM igniter electrode (part number 1179966) for the ICP/Tempstar/Heil RGS210HDEA0AAAA gas furnace. On each call for heat the control board energizes this igniter, which heats up to ignite the gas at the burners. The igniter element is brittle and degrades with every heating cycle, so it is one of the most common no-heat failures. A cracked or worn-out igniter glows weakly or not at all, causing the furnace to fail ignition, lock out, or short-cycle. Replacing it with the correct OEM electrode restores fast, reliable burner ignition.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Igniter Electrode
Brand ICP (Heil / Tempstar / Comfortmaker)
Application Gas furnace burner ignition
Fit RGS210HDEA0AAAA

Compatibility

Designed for the ICP/Tempstar/Heil RGS210HDEA0AAAA and related RGS-series gas furnaces that use the 1179966 igniter electrode. Match the mounting bracket and connector to your original before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect power, then verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter position, bracket, and wire routing.
  4. Remove — Unplug the igniter connector and remove the mounting screw; handle the old igniter only by its ceramic base.
  5. Install — Mount the new igniter without touching the element with bare fingers, reconnect the plug, and confirm correct spacing at the burner.
  6. Test — Restore gas and power, then run a heat cycle and verify the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace ignites intermittently or not at all
  • Igniter glows dim, uneven, or stays dark
  • Visible cracks or hot spots on the element
  • Repeated ignition lockouts or short cycling

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS210HDEA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS210HDEA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS210HDEA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online