Overview

This OEM hot surface igniter electrode (#1179966) is the ignition source for the ICP/Tempstar/Heil RGS183HDAA0AGAA gas furnace. On each heat call the control board sends voltage to the igniter, which glows to a high temperature and lights the burner gas. Hot surface igniters are a wear item — the brittle element naturally degrades from repeated thermal cycling, and cracks or hairline fractures stop the furnace from lighting. If your furnace clicks, draws air, but never fires, the igniter is the first part to check.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Igniter / Electrode
Brand ICP / Tempstar / Heil
Function Burner Ignition
Application Gas Furnace

Compatibility

Designed for the ICP/Tempstar/Heil RGS183HDAA0AGAA gas furnace and matched models using this electrode-style hot surface igniter. Confirm the mounting bracket and connector against your existing part.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, verify zero voltage with a multimeter, and shut off the gas.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position, wiring, and connector orientation before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw; handle the old element only by the ceramic base.
  5. Install — Mount the new igniter without touching the element with bare fingers, then reconnect per your photo.
  6. Test — Restore gas and power, start a heat call, and confirm the igniter glows and the burner lights.

Signs You Need a Replacement

  • Furnace runs the ignition sequence but never lights
  • Visible cracks, chips, or breaks in the igniter element
  • Igniter does not glow on a heat call
  • Repeated lockouts after several failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS183HDAA0AGAA — Furnace Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS183HDAA0AGAA — Furnace Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS183HDAA0AGAA — Furnace Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online