Overview

This OEM hot surface igniter assembly (igniter #1177663 with control board igniter #1186861) is built for the gas-heat section of the ICP / Tempstar / Heil WPG4364060RKB1 packaged gas-electric unit. The hot surface igniter glows red-hot on a call for heat to ignite the burner gas, while the igniter control circuit sequences the timing safely. Igniter elements are brittle and degrade with every heating cycle — they crack, develop hairline fractures, or lose the ability to reach ignition temperature, which leaves you with no heat, delayed ignition, or a furnace that locks out after several failed trials. Replacing the igniter with this OEM-spec part restores fast, reliable burner ignition and clears the most common cause of no-heat lockouts.

Specifications

Spec Value
Igniter Part Number 1177663
Control Board Igniter 1186861
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Fits Model WPG4364060RKB1
Fitment OEM

Compatibility

Designed for the gas-fired heating section of the ICP / Tempstar / Heil / Comfortmaker WPG4364060RKB1 packaged gas-electric unit. Match the connector style and mounting bracket to your original before installing.

Installation Guide

  1. Safety First — Shut off the gas and disconnect power, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter bracket position and wiring harness routing.
  4. Remove — Unplug the igniter connector and unscrew the mounting bracket. Handle the new igniter only by its ceramic base — never touch the silicon-nitride element.
  5. Install — Mount the new igniter so the element seats in the burner flame path, then reconnect the harness.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and the burners light within the normal trial period.

Signs You Need a Replacement

  • No heat with a furnace that locks out after several ignition trials
  • Igniter shows visible cracks or no longer glows
  • Delayed ignition or a small "poof" at burner light-off
  • Out-of-spec resistance reading across the igniter element

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WPG4364060RKB1 — Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WPG4364060RKB1 — Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WPG4364060RKB1 — Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.