Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Heil Tempstar Furnace Control Board Kit for RGS240HDEA0AAAA — OEM Replacement | Ships Today
ICP

ICP Heil Tempstar Furnace Control Board Kit for RGS240HDEA0AAAA — OEM Replacement | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part 1183618) is the integrated furnace control (IFC) that orchestrates every heat and cool cycle in your ICP / Heil / Tempstar RGS240HDEA0AAAA furnace. It manages the ignition sequence, inducer and blower timing, gas valve control, and the safety interlocks for limit switches, pressure switches, and flame sense. Supplied as a kit, it includes the mounting hardware and instructions needed for a clean swap. When the board fails you may see a dead unit, no inducer or blower, flashing diagnostic fault codes, short cycling, or ignition lockouts that persist after the igniter and sensors check out. Replacing a failed board with the correct OEM kit restores full, code-compliant operation.

Specifications

Spec Value
OEM Part Number 1183618
Type Integrated furnace control board kit
Brand ICP / Heil / Tempstar
Controls Ignition, inducer, blower, gas valve, safeties
Includes Board, mounting hardware, instructions

Compatibility

Engineered for the ICP / Heil / Tempstar RGS240HDEA0AAAA and related ICP-family furnaces. Match the board part number and connector layout to your existing control before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access — Remove the blower/control compartment service panel.
  3. Document — Photograph every harness connection and note any DIP switch or jumper settings.
  4. Remove — Unplug each connector, unfasten the old board, and transfer it from its standoffs.
  5. Install — Mount the new OEM board, replicate the original switch/jumper settings, and reconnect every harness per your photo.
  6. Test — Restore power and run a full heat cycle, confirming proper ignition, blower timing, and no fault codes.

Signs You Need a Replacement

  • Furnace is completely dead with no diagnostic LED.
  • Persistent flashing fault codes after other parts check out.
  • Inducer or blower fails to energize on a call.
  • Short cycling or ignition lockouts not traced to igniter/sensor.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS240HDEA0AAAA — OEM Replacement | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS240HDEA0AAAA — OEM Replacement | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS240HDEA0AAAA — OEM Replacement | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online