Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Gas Valve Support Bracket for RGS120HDAA0AGAA — OEM Mounting Hardware | Ships Today
ICP

ICP Gas Valve Support Bracket for RGS120HDAA0AGAA — OEM Mounting Hardware | Ships Today

SKU: 1178238 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM gas valve support bracket (part number 1178238) for the ICP / Heil / Tempstar RGS120HDAA0AGAA gas furnace. The bracket secures the gas valve assembly to the furnace burner box, holding the valve in correct alignment with the manifold and burner tubes so that gas flow, manifold pressure, and burner ignition all stay within spec. While it carries no electrical or gas rating of its own, it is a critical structural component: a missing, cracked, or corroded bracket allows the gas valve and manifold to sag or vibrate, which can crack flare fittings, stress the pilot/igniter assembly, and cause intermittent flame faults. Technicians most often replace this bracket after a valve swap, after corrosion damage in high-humidity installs, or when retrofitting a replacement gas valve that shipped without mounting hardware.

Specifications

Spec Value
Part Number 1178238
Type Gas Valve Support Bracket
Brand ICP / Heil / Tempstar (OEM)
Function Manifold / gas valve mounting
Material Stamped/galvanized steel
Fitment RGS120HDAA0AGAA

Compatibility

Designed as a direct-fit replacement for the RGS120HDAA0AGAA furnace and shares fitment across the RGS120 family and closely related ICP-built Heil, Tempstar, and Comfortmaker gas furnace platforms that use the same burner box layout. Always confirm against your unit's parts diagram before ordering.

Installation Guide

  1. Safety First — Shut off the gas supply at the manual valve and disconnect electrical power. Verify zero voltage at the control board with a multimeter.
  2. Access — Remove the furnace front service panel to expose the burner/manifold assembly.
  3. Document — Photograph the gas valve, manifold, and bracket orientation before removing anything.
  4. Remove — Disconnect the gas line union at the valve, unscrew the manifold/valve from the old bracket, then remove the bracket fasteners from the burner box.
  5. Install — Mount the new bracket in the same orientation, refit the gas valve and manifold, and torque fittings to spec.
  6. Test — Restore gas and power, then leak-check every joint with soap solution and confirm a clean burner ignition.

Signs You Need a Replacement

  • Visible cracking, bending, or rust-through on the existing bracket
  • Gas valve or manifold that sags, shifts, or vibrates during operation
  • Recurring flare-fitting gas leaks at the valve
  • Bracket missing from a replacement gas valve kit

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Gas Valve fit my ICP RGS120HDAA0AGAA — OEM Mounting Hardware | Ships Today?
Yes. This is the factory-specified OEM gas valve for the ICP RGS120HDAA0AGAA — OEM Mounting Hardware | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the gas valve on my ICP RGS120HDAA0AGAA — OEM Mounting Hardware | Ships Today?
Requires licensed HVAC technician. Gas valve work involves gas lines that must meet local building codes. Improper installation risks dangerous gas leaks. Buy the part yourself to save 40–60% on markup, then have your technician install it.
What symptoms mean I need a new gas valve?
Common symptoms: unusual noises, intermittent operation, complete failure, or visible damage. Visit our diagnostic hub for symptom-based troubleshooting.
Is this gas valve compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP gas valve?
Always use OEM. Gas valves must match exact pressure ratings, port configurations, and safety certifications. Non-OEM gas valves can create safety hazards and may violate building codes.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online