Overview

This is the OEM control board kit (part number 1183618) for the ICP Tempstar Heil RHH120H0CA0AAAA heat pump. The control board is the brain of the outdoor unit, managing the defrost cycle, reversing valve timing, compressor contactor signaling, and 24V low-voltage logic between the thermostat and the system. When this board fails, the unit may stop heating or cooling, get stuck in or out of defrost, short-cycle the compressor, or go completely unresponsive. A failed control board commonly shows blank diagnostics, blown fuses, or relays that won't energize. Replacing it with the correct OEM kit restores factory defrost timing and protection logic.

Specifications

Spec Value
Part Number 1183618
Type Control Board Kit (Defrost / Integrated)
Brand ICP (Tempstar / Heil)
Control Voltage 24V
Application Heat Pump Outdoor Unit
Fits Model RHH120H0CA0AAAA

Compatibility

Direct OEM fit for the ICP RHH120H0CA0AAAA heat pump. The RHH platform is shared across ICP's Tempstar, Heil, Comfortmaker, and related family brands, so this kit also services equivalent units built on the same chassis. Always verify your existing board part number against 1183618 before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the control panel access cover on the condensing unit.
  3. Document — Photograph all wire positions and terminal labels before disconnecting anything.
  4. Remove — Label and disconnect each connector, release the board standoffs/screws, and lift the old board out.
  5. Install — Mount the new board on the standoffs and reconnect every wire exactly per your photo.
  6. Test — Restore power, run a heating and cooling call, and confirm normal defrost and reversing-valve operation.

Signs You Need a Replacement

  • Unit won't switch between heating and cooling (stuck reversing valve logic)
  • System won't enter or exit defrost, causing outdoor coil icing
  • Compressor short-cycles or won't energize on a valid thermostat call
  • Blank or unresponsive board with repeatedly blown low-voltage fuses

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RHH120H0CA0AAAA — 24V Defrost Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RHH120H0CA0AAAA — 24V Defrost Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RHH120H0CA0AAAA — 24V Defrost Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online