Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGX060KFCA0AAA — OEM Ignition Board | Ships Today
ICP

ICP Furnace Control Board Kit for RGX060KFCA0AAA — OEM Ignition Board | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part 1183618) is the integrated furnace control that runs the entire heating sequence on the ICP/Tempstar/Heil RGX060KFCA0AAA gas furnace. It manages igniter timing, gas valve operation, inducer and blower relays, and the safety circuit that monitors limits, pressure switches, and flame sense. Sold as a kit, it includes the mounting hardware needed for a clean swap. When the board fails, the furnace may not respond to thermostat calls, short-cycle, run the blower continuously, or flash a fault code on the diagnostic LED. Replacing the board restores correct, safe heating sequencing.

Specifications

Spec Value
Part Number 1183618 (Kit, Control Board)
Type Integrated furnace control board kit
Brand ICP / Tempstar / Heil (OEM)
Functions Ignition, blower/inducer relays, safety circuit, diagnostics
Fitment Direct OEM replacement kit

Compatibility

Built for the ICP family RGX060KFCA0AAA 60,000 BTU gas furnace and related RGX-series furnaces specifying the 1183618 control board kit, including matching Tempstar, Heil, and Comfortmaker models on the same control platform.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the blower/control access panel.
  3. Document — Photograph every connector and wire location on the old board before removing anything.
  4. Remove — Unplug all harnesses, remove the mounting screws, and lift out the failed board.
  5. Install — Mount the new board with the included hardware and reconnect each harness exactly per your photos.
  6. Test — Restore power and run a full heat cycle, confirming ignition, blower, and a normal diagnostic LED.

Signs You Need a Replacement

  • Furnace does not respond to a thermostat heat call.
  • Blower or inducer runs constantly or not at all.
  • Repeated short-cycling or lockouts.
  • Diagnostic LED is dark or flashing a hard-fault code.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGX060KFCA0AAA — OEM Ignition Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGX060KFCA0AAA — OEM Ignition Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGX060KFCA0AAA — OEM Ignition Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online