Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGX048KFCA0AAA — OEM Integrated Control | Ships Today
ICP

ICP Furnace Control Board Kit for RGX048KFCA0AAA — OEM Integrated Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part number 1183618) is the exact replacement integrated furnace control for the ICP Tempstar Heil RGX048KFCA0AAA. The control board is the brain of the furnace — it sequences the entire heating cycle, managing the inducer motor, hot surface igniter, gas valve, and blower while monitoring safety circuits such as the pressure switch, limit switch, and flame sensor. When the board fails, the furnace may not respond to the thermostat at all, may light intermittently, may run the blower continuously, or may flash diagnostic error codes via its onboard LED. Supplied as a complete kit, this control includes the mounting and wiring components needed for a clean OEM replacement. Always record any error codes and the existing wiring before swapping the board.

Specifications

Spec Value
OEM Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Function Ignition, Blower & Safety Sequencing
Includes Control Board + Mounting/Wiring Kit
Diagnostics Onboard LED Fault Codes

Compatibility

Direct-fit OEM kit for the ICP Tempstar Heil RGX048KFCA0AAA. This integrated control platform is shared across many ICP-family gas furnaces; verify the connector layout and kit instructions against your unit before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph every connector and harness location before unplugging.
  4. Remove — Unplug all connectors, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board per the kit instructions and reconnect each harness exactly as photographed.
  6. Test — Restore power and run a full heat cycle, confirming a normal LED status and proper sequencing.

Signs You Need a Replacement

  • Furnace does not respond to the thermostat
  • Blower runs continuously or won't start
  • Diagnostic LED flashing a hard-fault code
  • Intermittent or no ignition despite good igniter and gas valve

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGX048KFCA0AAA — OEM Integrated Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGX048KFCA0AAA — OEM Integrated Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGX048KFCA0AAA — OEM Integrated Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online