Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS303SSFA0AAAA — OEM | Ships Today
ICP

ICP Furnace Control Board Kit for RGS303SSFA0AAAA — OEM | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM control board kit (part number 1183618) for the ICP / Tempstar / Heil RGS303SSFA0AAAA gas furnace. The integrated furnace control board is the brain of the system — it sequences the inducer, igniter, gas valve, and blower, monitors safety inputs like the pressure switch and limit, and manages flame sensing and fault diagnostics. When the board fails, the furnace may not respond to the thermostat, lock out on false faults, fail to energize the blower, or behave erratically. This kit includes the matched replacement board for a direct OEM swap.

Specifications

Spec Value
Part Number 1183618
Description Control Board Kit
Type Integrated Furnace Control (IFC)
Brand ICP / Tempstar / Heil
Control Voltage 24 VAC
Fitment OEM

Compatibility

Built for the ICP-manufactured RGS303SSFA0AAAA furnace and equivalent Tempstar, Heil, and Comfortmaker models. Verify the board part number and connector layout against your existing control before installing.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control/blower compartment service panel.
  3. Document — Photograph every harness plug and wire location before disconnecting; note any dip-switch or jumper settings.
  4. Remove — Unplug each connector, release the board standoffs/screws, and lift out the old board.
  5. Install — Mount the new board, transfer any settings, and reconnect each harness per your photo.
  6. Test — Restore power and run a full heat cycle, confirming inducer, ignition, gas valve, and blower sequence correctly with no fault codes.

Signs You Need a Replacement

  • Furnace completely unresponsive to thermostat calls.
  • Repeated or false fault/lockout codes on the diagnostic LED.
  • Blower or inducer fails to energize in the correct sequence.
  • Burnt spots, corrosion, or scorched relays visible on the board.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS303SSFA0AAAA — OEM | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS303SSFA0AAAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS303SSFA0AAAA — OEM | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online