Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS303SSAA0AAAA — OEM 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS303SSAA0AAAA — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM control board kit, part number 1183618, for ICP, Tempstar, and Heil gas furnaces. The integrated furnace control board is the brain of the system: it sequences ignition, manages the inducer and blower motors, monitors safety devices such as the pressure switch and limit, controls timing for fan-on and fan-off delays, and flashes diagnostic fault codes through its onboard LED. When the board fails the furnace may go completely dead, fail to ignite, leave the blower running continuously, or throw erratic and inconsistent fault codes. Supplied as a kit, this OEM board includes the components needed for a correct, reliable replacement so the furnace returns to proper sequencing and safe operation.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil OEM
Application Gas Furnace Control
Fitment OEM Replacement

Compatibility

Engineered as the factory replacement control board kit for the ICP Tempstar Heil RGS303SSAA0AAAA gas furnace. ICP uses this board across related furnace models; match your existing board part number and connector layout before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the blower-compartment service panel to expose the control board.
  3. Document — Photograph every harness connector and wire location before disconnecting; connectors are keyed but labeling prevents errors.
  4. Remove — Unplug each harness, release the board from its standoffs or screws, and lift it out.
  5. Install — Mount the new board, then seat each harness connector firmly in its matching port per your photo.
  6. Test — Restore power, run a full heat cycle, and confirm correct ignition, blower timing, and a steady status LED with no fault codes.

Signs You Need a Replacement

  • Furnace is completely unresponsive with no status LED
  • No ignition sequence despite a valid call for heat
  • Blower runs continuously or fails to start
  • Erratic, inconsistent, or unexplained diagnostic fault codes

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS303SSAA0AAAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS303SSAA0AAAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS303SSAA0AAAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online