This genuine OEM control board kit (part number 1183618) is the integrated furnace control that manages the entire heating sequence on ICP, Heil, and Tempstar gas furnaces including the RGS303SRFA0AAAA. The board takes the thermostat call, runs the inducer and pressure-switch proving, energizes the igniter and gas valve, times the blower on and off delays, and monitors flame and safety limits. It is the brain of the furnace — when it fails, the equipment cannot operate safely or reliably. The kit ships with the mounting hardware and instructions needed for a complete replacement.

Control boards fail from power surges, overheating, corrosion, cracked solder joints, and burned relays. Symptoms range from a completely dead furnace to erratic blower behavior, ignition lockouts that are not caused by the igniter or flame sensor, and diagnostic LED fault codes that do not clear after the obvious components are checked. Installing the correct OEM board restores the factory control sequence and the built-in safety logic.

Specifications

Spec Value
Part Number 1183618
Type Integrated furnace control board kit
Brand ICP / Heil / Tempstar
Function Ignition, blower timing, and safety control
Application Gas furnace
Fitment OEM replacement kit

Compatibility

Direct OEM replacement for the RGS303SRFA0AAAA and other ICP / Heil / Tempstar / Comfortmaker gas furnaces specifying the 1183618 control board kit. Confirm the board part number and connector layout against your existing control before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, shut off the gas, and verify zero voltage before touching the board.
  2. Access — Remove the furnace control-compartment service panel to expose the board.
  3. Document — Photograph every connector and wire location on the old board before disconnecting anything — this is the most important step on a control board swap.
  4. Remove — Unplug each harness connector, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board with the supplied hardware and reconnect each connector to the matching position per your photos.
  6. Test — Restore gas and power, run a full heat cycle, and confirm proper inducer, ignition, gas valve, and blower sequencing with no fault codes on the diagnostic LED.

Signs You Need a Replacement

  • Furnace completely dead with no response to a thermostat call
  • Erratic or continuous blower operation outside normal timing
  • Ignition lockouts not resolved by replacing the igniter or flame sensor
  • Diagnostic LED fault codes pointing to the control, or visible burn marks and corrosion on the board

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS303SRFA0AAAA — Integrated Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS303SRFA0AAAA — Integrated Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS303SRFA0AAAA — Integrated Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.