Overview

This OEM control board kit (ICP part #1183618) is the integrated furnace control (IFC) that manages your RGS303SFAA0AAAA system's entire heating sequence — ignition timing, gas valve and inducer operation, blower fan on/off delays, safety interlocks, and diagnostic fault codes. The board reads inputs from the thermostat, pressure switch, limit switches, and flame sensor, then sequences each component safely. When a control board fails you may see a completely dead furnace, blower or inducer that won't run, flashing diagnostic LED fault codes, or intermittent no-heat events. Supplied as a complete kit, this OEM control board includes the correct firmware and connector layout for your unit, restoring reliable, code-correct operation without the guesswork of a universal board.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Heil / Tempstar / Comfortmaker
Application Gas Furnace Control
Fit OEM Replacement Kit

Compatibility

Factory replacement control board kit for ICP / Tempstar / Heil model RGS303SFAA0AAAA and related ICP-family furnaces using this integrated furnace control. Confirm OEM number 1183618 and the connector/terminal layout against your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter; shut off the gas.
  2. Access — Remove the blower/service panel to reach the control board.
  3. Document — Photograph every connector, plug, and wire position before disconnecting anything.
  4. Remove — Unplug the harness connectors, release the board from its standoffs/mounting screws, and remove it.
  5. Install — Mount the new board, transfer any jumpers/links, and reconnect every connector exactly per your photo.
  6. Test — Restore gas and power, run a full heat cycle, and verify the diagnostic LED shows normal operation.

Signs You Need a Replacement

  • Furnace completely dead with no LED activity
  • Flashing diagnostic fault/error codes
  • Blower or inducer won't run, or runs continuously
  • Intermittent no-heat or random lockouts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS303SFAA0AAAA — OEM | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS303SFAA0AAAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS303SFAA0AAAA — OEM | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.