ICP Furnace Control Board Kit for RGS303LRAA0AAAA — OEM 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS303LRAA0AAAA — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

The ICP control board kit (OEM part 1183618) is the integrated furnace control (IFC) brain of the RGS303LRAA0AAAA gas furnace. It sequences the ignition cycle, manages the inducer and blower, monitors limits and flame proving, and runs the onboard diagnostic LED. When this board fails, the furnace may be completely dead, stuck in lockout, or unable to run the blower or inducer. This OEM kit includes the matched board for a direct, reliable replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Control Voltage 24V Low Voltage
Application Gas Furnace Ignition & Blower Control
Fitment OEM Replacement

Compatibility

Designed for the ICP/Tempstar/Heil RGS303LRAA0AAAA gas furnace and related RGS-series units using the 1183618 control kit. Verify the existing board part number and connector layout against your unit before installing.

Installation Guide

  1. Safety First — Disconnect electrical power and shut off gas; verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/service panel.
  3. Document — Photograph every wire harness and terminal connection before disconnecting.
  4. Remove — Unplug all connectors, remove the mounting screws/standoffs, and lift out the failed board.
  5. Install — Mount the new board, transfer any jumpers/settings, and reconnect each harness exactly per your photos.
  6. Test — Restore power and gas, run a full heat cycle, and confirm normal LED status and proper inducer, ignition, and blower sequencing.

Signs You Need a Replacement

  • Furnace completely unresponsive on a call for heat
  • Blower or inducer motor will not run despite good motors
  • Diagnostic LED flashing a hard-fault/board code or no light at all
  • Intermittent operation, random resets, or repeated unexplained lockouts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS303LRAA0AAAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS303LRAA0AAAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS303LRAA0AAAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online