ICP Furnace Control Board Kit for RGS300SSFA0AAAA — OEM 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS300SSFA0AAAA — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM control board kit (part number 1183618) for ICP, Tempstar, and Heil gas furnaces. The integrated furnace control board is the brain of the system — it sequences the ignition cycle, manages the inducer and blower, monitors safety limits and the flame signal, and times each stage of heating. When the board fails you may see no response on a call for heat, blower or inducer that won't start, error codes flashing on the diagnostic LED, or short cycling. This kit includes the replacement board for a clean, reliable swap that restores full furnace control.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Function Ignition, Blower, Inducer & Safety Sequencing
Diagnostics Onboard LED Fault Codes
Fit OEM Replacement Kit

Compatibility

Direct-fit replacement for the ICP/Tempstar/Heil RGS300SSFA0AAAA gas furnace and other RGS300-series units that use the 1183618 control board kit. Match your existing board part number before ordering, as furnace control boards are model-specific.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control compartment service panel.
  3. Document — Photograph every harness plug and wire location on the old board before disconnecting.
  4. Remove — Unplug each connector, release the board standoffs, and lift out the failed board.
  5. Install — Mount the new board, transfer all connectors to the matching ports per your photo, and confirm jumper/dip settings.
  6. Test — Restore power and run a full heat cycle, watching the diagnostic LED for normal operation.

Signs You Need a Replacement

  • No response from the furnace on a call for heat.
  • Blower or inducer motor will not energize.
  • Persistent fault codes or a dead diagnostic LED.
  • Short cycling or erratic ignition sequencing.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS300SSFA0AAAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS300SSFA0AAAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS300SSFA0AAAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.