Overview

This genuine OEM control board kit, ICP part number 1183618, is the integrated furnace control (IFC) that runs the entire heating and blower sequence on your RGS300SSEA0AAAA. It manages the igniter, gas valve, inducer, blower timing, and safety lockouts while monitoring the limit and flame-sensing circuits. When this board fails, symptoms range from a completely dead furnace to erratic blower behavior, repeated lockouts, or fault codes on the diagnostic LED. The kit ships as a direct OEM replacement so the furnace returns to its factory control logic and timing.

Specifications

Spec Value
OEM Part Number 1183618
Description Control Board Kit (Integrated Furnace Control)
Type Furnace Ignition / Blower Control
Brand ICP / Tempstar / Heil
Application Gas Furnace
Fitment OEM Direct Replacement Kit

Compatibility

Built as the factory replacement for the ICP/Tempstar/Heil RGS300SSEA0AAAA and related RGS-series single-stage furnaces that specify OEM part 1183618. Kits include the board and mounting hardware; transfer any wiring harness or jumper settings from your old board exactly. Confirm the part number printed on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control/blower compartment service panel.
  3. Document — Photograph every connector, harness, and jumper position on the old board before disconnecting.
  4. Remove — Unplug each connector, release the mounting standoffs or screws, and lift out the failed board.
  5. Install — Mount the new board, match any jumper or DIP settings, and reconnect each harness exactly per your photo.
  6. Test — Restore power and run a full heat cycle, confirming the diagnostic LED shows normal operation.

Signs You Need a Replacement

  • Furnace is completely unresponsive to thermostat calls.
  • Diagnostic LED is dark or flashing a hard-fault code.
  • Blower or inducer runs erratically or will not stage correctly.
  • Visible burn marks, corrosion, or scorched relays on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS300SSEA0AAAA — OEM | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS300SSEA0AAAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS300SSEA0AAAA — OEM | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.