Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS300SFEA0AAAA – OEM Integrated Control | Ships Today
ICP

ICP Furnace Control Board Kit for RGS300SFEA0AAAA – OEM Integrated Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM control board kit, ICP part number 1183618, for ICP, Tempstar, and Heil gas furnaces. The integrated furnace control (IFC) is the brain of the furnace — it manages the ignition sequence, sequences the inducer, igniter, gas valve, and blower, monitors safety limits and the flame signal, and runs self-diagnostics via its onboard fault LED. Supplied as a complete kit, it includes the board and the mounting/wiring hardware needed for a clean swap. A failed board can cause no-heat conditions, erratic operation, blower problems, or repeated lockouts.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Function Manages ignition, blower, safeties, diagnostics
Includes Control board and mounting/wiring kit
Fitment OEM Direct Replacement

Compatibility

Direct-fit OEM replacement for the ICP / Tempstar / Heil RGS300SFEA0AAAA furnace and other RGS-family models that originally shipped with kit 1183618. Confirm against your unit's parts breakdown before ordering.

Installation Guide

  1. Safety First – Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter. Shut off the gas supply.
  2. Access – Remove the control/blower compartment service panel.
  3. Document – Photograph every wire and connector on the old board before disconnecting; note plug locations.
  4. Remove – Unplug all harnesses and remove the board's mounting screws/standoffs, then lift out the old board.
  5. Install – Mount the new board using the included hardware and reconnect each harness exactly per your photo.
  6. Test – Restore gas and power, run a full heat cycle, and verify the diagnostic LED shows normal operation with no fault codes.

Signs You Need a Replacement

  • No-heat condition with no response on a call for heat
  • Diagnostic LED flashing a hard-fault or control-failure code
  • Blower or inducer running erratically or not sequencing correctly
  • Repeated lockouts not traced to the igniter, flame sensor, or gas valve

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS300SFEA0AAAA – OEM Integrated Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS300SFEA0AAAA – OEM Integrated Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS300SFEA0AAAA – OEM Integrated Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online