Overview

This is the genuine OEM control board kit (part number 1183618) for the ICP / Tempstar / Heil RGS300SFBB0AGAA gas furnace. The integrated furnace control board is the brain of the system — it manages the ignition sequence, sequences the inducer, igniter, gas valve, and blower, monitors safety limits and flame, and flashes diagnostic fault codes. When the board fails you may see no response to a heat call, blank or erratic LED codes, components energizing out of sequence, or intermittent no-heat faults. This complete kit includes the board so you can restore full, safe furnace operation in one repair.

Specifications

Spec Value
OEM Part Number 1183618
Type Integrated Furnace Control Board Kit
Function Ignition Sequencing, Safety & Diagnostics
Brand ICP / Tempstar / Heil
Application Gas Furnace
Fitment OEM Replacement Kit

Compatibility

Direct-fit replacement for the ICP Tempstar Heil RGS300SFBB0AGAA furnace and related ICP-family RGS models specifying the 1183618 control board kit. Verify the board part number and connector layout against your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace service panel to expose the control board.
  3. Document — Photograph every wire harness and connector position before disconnecting; note any jumper or dip-switch settings.
  4. Remove — Unplug each connector, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board, match any switch/jumper settings, and reconnect every harness exactly per your photo.
  6. Test — Restore power, run a full heat cycle, and confirm correct sequencing and no fault codes on the diagnostic LED.

Signs You Need a Replacement

  • No response from the furnace on a valid call for heat.
  • Blank, missing, or rapidly flashing error LED codes.
  • Inducer, igniter, or blower energizing out of sequence.
  • Burnt smell, scorch marks, or visibly damaged relays/traces on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS300SFBB0AGAA — OEM Ignition Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS300SFBB0AGAA — OEM Ignition Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS300SFBB0AGAA — OEM Ignition Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online