This is a genuine OEM furnace control board kit, ICP part number 1183618, for ICP, Tempstar, and Heil gas furnaces. The integrated control board is the brain of the furnace — it manages the ignition sequence, monitors safety circuits and limit switches, sequences the inducer, igniter, gas valve, and blower, and runs the self-diagnostic flash codes. A failed board produces symptoms ranging from a completely dead furnace to erratic blower operation, no ignition, or repeated lockouts. Because the board ties together every major component, it is typically diagnosed after confirming that sensors, limits, and the igniter test good. This kit includes the board and the mounting/wiring hardware needed for a clean OEM replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Application Gas Furnace Control
Fitment OEM Direct Replacement

Compatibility

Direct-fit OEM replacement kit for ICP-family furnaces including model RGS300SFAA0AAAA and related Tempstar and Heil units originally supplied with part 1183618. Confirm the board layout and connector configuration against your existing control before ordering.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the blower or control compartment service panel.
  3. Document — Photograph every connector and wire on the existing board before disconnecting.
  4. Remove — Unplug each harness, release the board standoffs or screws, and lift out the old board.
  5. Install — Mount the new board from the kit and reconnect each harness to the matching connector per your photo.
  6. Test — Restore power and confirm a full, clean ignition-to-blower sequence with no fault flash codes.

Signs You Need a Replacement

  • Furnace completely dead with no diagnostic LED
  • No ignition sequence despite a valid call for heat
  • Erratic blower or inducer behavior, or random lockouts
  • Visible scorching, burnt traces, or corroded connectors on the board

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS300SFAA0AAAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS300SFAA0AAAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS300SFAA0AAAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.