This genuine OEM control board kit (part #1183618) is the integrated furnace control for the ICP / Tempstar / Heil RGS300SDAA0AAAA gas furnace. The board is the brain of the furnace: it sequences the entire heat cycle — inducer, ignition, gas valve, and blower timing — while monitoring safety inputs such as limits and flame sense. It also typically manages the thermostat call, blower-off delays, and onboard diagnostic LED fault codes. When the board fails, the furnace may be completely dead, fail to ignite, run the blower continuously, or flash error codes that don't clear. Supplied as a complete kit, this OEM control restores correct sequencing and protects the rest of the furnace by enforcing its built-in safety logic.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Application Gas furnace ignition & blower control
Fitment OEM

Compatibility

Built for the ICP/Tempstar/Heil RGS300SDAA0AAAA furnace and shared-platform models that use this control kit. Confirm the board part number printed on your existing control against 1183618 before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control compartment panel.
  3. Document — Photograph every wire and connector on the board, and note the dip-switch / jumper settings.
  4. Remove — Unplug each harness, release the board standoffs, and lift out the old control.
  5. Install — Mount the new board, transfer any settings, and reconnect every connector exactly per your photo.
  6. Test — Restore power and run a full heat cycle, confirming proper inducer, ignition, and blower sequencing with no fault codes.

Signs You Need a Replacement

  • Furnace is completely unresponsive with no diagnostic LED
  • No ignition sequence despite a thermostat call
  • Blower runs continuously or fails to start
  • Persistent or non-clearing diagnostic fault codes

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS300SDAA0AAAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS300SDAA0AAAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS300SDAA0AAAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.